CertBus ensures to provide the most update MD0-205 Mcdata Certified Storage network designer exam exam questions with the most accurate answers. CertBus MD0-205 are the most complete and authoritative exam preparation materials with which one can pass the MD0-205 exam in an easy way. Preparing for McDATA MD0-205 Mcdata Certified Storage network designer exam exam is really a tough task to accomplish. But CertBus will simplified the process.
We CertBus has our own expert team. They selected and published the latest MD0-205 preparation materials from McDATA Official Exam-Center: http://www.certgod.com/MD0-205.html
QUESTION NO:80
A healthcare provider has two applications that they need to redundantly protect in a SAN environment.
Their patient record application runs on Oracle 11i and consists of many small, randomly accessed files.
The database is kept on three clustered Sun servers and currently uses 30 TB of data space. Their
imaging application that retains and manages x-rays, consists of Filenet, CommonStore, and TSM
running on an IBM Power750 server, and is currently using 65 TB of data space. Which of the following
disk solutions meets the customer\’s requirement?
A. IBM System Storage DS8700 2 way
B. IBM System Storage DCS9900
C. IBM System Storage DS8700 4 way
D. IBM XIV Storage System
Correct Answer: C
ExamReal.com — 100% Real QandAs | 100% Real Pass
QUESTION NO:120
A banking company has deployed the Application Center for internal use. Before users can see the mobile
client application in the list of available applications, which property of the mobile client application must be
set to true?
A. Label
B. Package
C. Installer
D. Recommended
Correct Answer: C
QUESTION NO:46
Which two components are created during configuration of space-efficient storage in an extent pool?
A.
volume and virtual space
B. background copy and target copy
C.
virtual space and repository space
D.
source volume and target volume
Correct Answer: C
QUESTION NO:39
An IBM Business Partner has sold a DS5020 and new IBM SAN switches to replace a customer EMC
storage infrastructure. The customer dissatisfaction has arisen during the installation because according to
the DS5020 interoperability matrix, two HP Proliant servers running Exchange have FC HBAs that are not
supported. Which of the following is the most probable cause of the customer dissatisfaction?
A. The EMC storage specialist has not participated in the TDA meeting
B. The FC HBAs are 4 Gbps technology
C. The Technical and Delivery Assessment review actions were not executed
D. The customer should have checked that the HBAs are supported according to the HP storage
interoperability matrix
Correct Answer: C
ExamReal.com — 100% Real QandAs | 100% Real Pass
QUESTION NO:29
Companycom wants to apply a PTF to the p5 590 system. After doing a preview install, the output
shows there is insufficient space in the /usr filesystem. The root volume group has no available
physical partitions left. They do not want to add additional disk drives to the system, but have a
jfs2 filesystem that is only 8% used. What could they do to utilize space in the jfs2 filesystem to
apply this PTF?
A. Backup the filesystem and recreate smaller
B. Use the chfs to reduce the filesystem size
C. Use cplv to copy filesystem to smaller size
D. Use migratepv to copy filesystem to smaller size
Answer: B